Unlock Superior Corrosion Protection with DualGuard 2000: Engineered for Safety and Durability in Industrial Environments

Explore the Cutting-edge DualGuard 2000 for Superior Corrosion Resistance and Fire Safety in Demanding Environment

Our clients can expect unparalleled product support and service. Field installation, modification and repair services are offered for all of our products from a first class service department.

DualGuard UL& FM Listed Firesafe Ducting

Are you worried about meeting the Insurance Underwriter and Building Code Requirements for corrosive fume exhaust?

 

Your worries are over!

Insurance underwriters and local building codes routinely require the use of low-smoke, fire-safe materials in the construction of process facilities. DualGuard 2000 meets these requirements without the use of either internal or external sprinklers, making it less expensive to install. Building Codes in the United States, Canada, and many other locations around the globe, including those of B.O.C.A. and the U.B.C./I.B.C., require testing to ASTM E-84 for flame spread and smoke development. The duct must exhibit a flame spread of 25 or less and a smoke development of 50 or less on both the inside and the outside of the duct to be used without sprinklers. DualGuard 2000 has been tested by both Factory Mutual and Underwriters Laboratories. Its flame spread of 5 and smoke development of 10, on both the inside and outside of the duct, assures you that a DualGuard system will meet building codes and insurance requirements.

  • Flame Spread of 5 on both the inside and outside of the duct (ASTM E-84)
  • Smoke Development of 10 on both the inside and outside of the duct (ASTM E-84)
  • VeilGuard in the corrosion liner for premium corrosion resistance
  • Built to long-established industry guidelines for corrosion-resistant fiberglass composites
  • Easy to assemble with a variety of joining techniques Independent 3rd party QA auditing by Factory Mutual and U.L

Factory Mutual Approvals

  • DualGuard 2000 passed Factory Mutual’s new, tougher 4922 test procedure for non-sprinkler fume and smoke removal systems File no. 4B1A5M.AM.
  • DualGuard 2000 passed Factory Mutual’s new 4910 test procedure for Clean Room Approved Materials – File No. 3006453.

Underwriters Laboratories Listing

  • DualGuard 2000 passed the U.L. 181 test procedure, leading to its listing as a Class 1 Duct in accordance with U.L. requirements – File No. MH26567.
  • U.L. 181 Listing meets NFPA and the International Mechanical Code (IMC) requirements.

You’ll share our passion: fire-safe and easy to install!

DualGuard 2000 takes the heat when exposed to a direct flame source and will continue to exhaust hazardous chemical process fumes during a fire. DualGuard does not require collapsing sleeves or dampers, which would prevent hazardous smoke removal. DualGuard will not generate toxic gases that can endanger employees.

You’ll share our passion: fire safe and easy to install! The advantages of the DualGuard resin system include corrosion resistance, high-temperature resistance, not readily burning, off-low smoke, and low smoke toxicity.

Shown below is an example of an engineered solution from Composites USA with DualGuard 2000, a reduced cross with integral dampers. DualGuard 2000 duct and dampers are available in almost every conceivable configuration with sizes as small as 1/2 inch and as large as 24 feet in diameter. Fittings include elbows, transitions, tees, reducers, stacks, fume hoods, dampers and more. See our product catalog or visit our web site for a complete product listing.

Engineered with confidence – chemical, mechanical, and professional engineers on staff. Manufactured with state-of-the-art filament winding, layup, thermoform, and resin transfer molding processes. Quality guaranteed with independent audits by Factory Mutual, U.L. and U.S. Government to Mil-Spec 45208.

 

DualGuard Meets the Construction Standards for Corrosive Fume Fiberglass Duct!

Dual Guard is built to the same standards that have guided the fiberglass corrosion industry for over thirty years.

  1. Inner Surfacing Layer—A fluoropolymer surfacing veil results in a 25 mil (0.63mm / 0.025 inch) thick reinforced resin-rich surface. Not all FM ducts provide a corrosion veil; none use a premium veil.
  2. Interior Layer: reinforced with non-continuous glass strands at 20%—30% by weight, with fiber lengths from 0.5 – 2.0 inches.
  3. Structural Layer – continuously wound fiberglass to provide optimal strength for a given application. This layer is typically 65% by weight glass.
  4. External Layer: Woven fiberglass cloth for ease of bonding using either conventional fiberglass joining techniques or proprietary Composites USA bonding systems.

About U.L. Testing—U.L. testing involves destructive product tests for flame and smoke generation, strength pressure, vacuum, tension, bending—impact and puncture resistance, erosion, and a number of other criteria, including long-term stability at low and elevated temperatures. In addition to assuring the product will not burn, U.L. Listing assures the customer that the product provided is built to provide years of service in rugged industrial environments.

About FM Test Protocols—Factory Mutual has long-tested products for flame propagation and smoke generation. Duct products that successfully pass these critical tests are given FM Approval to their 4922 protocol, which allows corrosive fume and smoke exhaust ducts to be installed without sprinklers.

The key tests for FM 4922:

  1. The ASTM E-84 tunnel test measures flame spread and smoke generation in a controlled burn chamber.
  2. 50 kW-scale FMRC Flammability Apparatus Test to measure the Critical Heat Flux (CHF – a heat flux at which ignition is not expected to occur) and the Thermal Response Parameter (TRP – a measure of ignition resistivity), as well as the ignition and peak Chemical Heat Release Rate (CHRR).
  3. The oxygen bomb calorimeter (for heat content) is in accordance with D 240-85.
  4. Auto-ignition in accordance with ASTM D 1929-77.
  5. The Factory Mutual horizontal/vertical burn test measures flame propagation, temperature rise, and strength retention during actual duct fires at temperatures over 1000°F.

Here is a view of the configuration for the FM 4922 horizontal test, with a heptane-fed fire exhausted through 24 feet of duct. Temperatures can reach 1500°F during the 25-minute two-stage test. Key criteria include flame and smoke generation, maintenance of structural integrity, and limits of the duct temperature rise.

Factory Mutual also has a Clean Room Materials Test Protocol, 4910

The 4910 protocol builds upon the results of the 4922 testing with additional samples and testing to ensure suitability for Clean Room product installations. The 4910 test evaluates materials’ fire propagation behavior, potential for smoke contamination, and potential for contamination by corrosive products of combustion.

 

The key tests for FM 4910:

  1. The thermal response parameter (TRP) is calculated using ignition tests, during which samples are exposed to increasing heat flux levels up to 60 kW/m2.
  2. Fire propagation tests, in which samples are burned in the presence of 40% oxygen, help generate the fire propagation index (FPI).
  3. Combustion tests, similar in nature to the fire propagation tests, run at 21% oxygen and are used to generate smoke index (SI) numbers.

From the above tests, Factory Mutual calculates a Smoke Damage Index (SDI) which is the total mass of smoke generated to the total mass of the material loss. The 4910 upper limit for the SDI is 0.40. FPI values are used for the classification of materials as either nonpropagating (good) or propagating. The 4910 upper limit for the FPI is 6.0.

 

Corrosion Resistance that will exceed your needs!

VeilGuard is one of the most chemically resistant polymers available today. In addition to its chemical resistance and a U.L. 94 V-0 rating, VeilGuard also has low flammability and smoke generation advantages. It is resistant to chemical attack from most acids, bases, and solvents, has excellent temperature resistance, and has better barrier properties than PTFE or FEP. The use of this material in the corrosion liner for DualGuard 2000 series products offers significant advantages compared to systems with glass, polyester, or no liner reinforcement.

SERIES 2000 Copolymer Resin

The resin used in the DualGuard 2000 system offers excellent corrosion resistance in and of itself. As noted above, the VeilGuard veil used in DualGuard 2000 products offers better corrosion resistance than any other competing veil. Used together, DualGuard 2000 offers an unbeatable combination of properties.

The resin system used in DualGuard 2000 is a proprietary copolymer product developed specifically for enhanced corrosion resistance, low flame propagation, and low smoke development in pipe and duct applications. In addition to its superior fire performance, very low smoke evolution, and higher temperature performance, Series 2000 resin offers excellent corrosion resistance to a wide variety of acids, solvents, and bases. Specifically, this applies to the types of vapors typically found in exhaust streams from laboratory, semiconductor, plating, and pharmaceutical operations. Tests of DualGuard resin demonstrated fatigue strengths (cycles to failure) equivalent to an epoxy pipe and better fatigue strength than a vinyl ester.

ASTM C-581 test results are shown for DualGuard 2000 exposed to various reagents. These measurements reflect flex modulus and strength retention following full liquid immersion for one year—a service much more severe than a duct installation, where exposures are typically diluted vapors. As seen from the charts, DualGuard 2000 compares very favorably against fire retardant vinyl ester in various exposure conditions.

Latest Technical Articles 

Maximizing Cost Savings: The Impact of DualGuard FM UL Approvals

Uncover how DualGuard FM UL approvals revolutionize cost-effectiveness. Discover key insights on maximizing savings through cutting-edge technologies. Elevate your safety standards while optimizing financial efficiency.

Elevating Safety in Corrosive Environments: The Game-Changing Power of FlameGuard E84 Low Flame Ducting

Dive into the revolutionary world of FlameGuard E84 Low Flame Ducting. Uncover how this innovation reshapes safety standards in corrosive settings, ensuring optimal protection and peace of mind.

Revolutionizing Industrial Safety with DualGuard UL & FM Listed Firesafe Ducting

One of the latest innovations leading this charge is the DualGuard UL & FM Listed Firesafe Ducting from Composites USA. This advanced ducting system is designed to provide unparalleled fire safety and reliability in demanding industrial environments.

Contact Us

Please enable JavaScript in your browser to complete this form.
Name

One Peninsula Drive, North East, MD 21901

+1-410-287-2700

info@compositesusa.com